Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 130
Filtrar
2.
Pathologe ; 39(Suppl 2): 236-240, 2018 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-30406831

RESUMO

BACKGROUND: The interaction of our immune system with breast cancer (BC) cells prompted the investigation of tumor-infiltrating lymphocytes (TILs) and targeted, tumor antigen-specific immunotherapy. OBJECTIVES: Correlation between TILs and pathological complete response (pCR) after neoadjuvant systemic therapy (NACT). Tumor-specific antigens (TSAs) in HER2+ and triple negative BC and establishment of TSA-specific therapies within the interdisciplinary TILGen study. METHODS: Illustration of the TILGen study design. Assessment of TILs and correlation with pCR within this BC study. RESULTS: pCR was achieved in 38.4% (56/146) and associated with estrogen receptor/progesterone receptor negative (ER-/PR-) and HER2+ tumors. Lymphocytic predominant BC (LPBC) was found in 16.4% (24/146), particularly in ER-/PR- (ER-: 27.3% vs. ER+: 9.9%, PR-: 22.3% vs. PR+: 8.2%), large, and poorly differentiated BC. TILs were significantly correlated with pCR in multivariate analysis. In LPBC, pCR was achieved in 66.7%, whereas it was 32.8% in non-LPBC. CONCLUSIONS: First results confirm the influence of the human immune system on the response to NACT in HER2+ and triple negative BC. TSA-specific immunotherapy might improve the outcome in BC patients but there is an urgent need for comprehensive studies to further investigate this issue.


Assuntos
Neoplasias da Mama , Biomarcadores Tumorais , Humanos , Linfócitos , Linfócitos do Interstício Tumoral , Terapia Neoadjuvante , Prognóstico , Receptor ErbB-2 , Receptores de Estrogênio , Neoplasias de Mama Triplo Negativas
3.
Geburtshilfe Frauenheilkd ; 77(2): 169-175, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28331239

RESUMO

Introduction The placement of intramammary marker clips has proven to be helpful for tumor localization in patients undergoing neoadjuvant chemotherapy and breast-conserving surgery. The purpose of our study was to investigate the feasibility of using a clip marker system for breast cancer localization and its influence on the imaging assessment of treatment responses after neoadjuvant chemotherapy. Patients and Methods Between March and June 2015, a total of 25 patients (n = 25), with a suspicion of invasive breast cancer with diameters of at least 2 cm (cT2), underwent preoperative sonographically guided core needle biopsy using a single-use breast biopsy system (HistoCore™) and intramammary clip marking using a directly adapted clip system based on the established O-Twist Marker™, before their scheduled preoperative neoadjuvant chemotherapy. Localization of the intramammary marker clip was controlled by sonography and digital breast tomosynthesis. Results Sonography detected no dislocation of intrammammary marker clips in 20 of 25 patients (80 %), while digital breast tomosynthesis showed accurate placement without dislocation in 24 patients (96 %) (p < 0.05). There was no evidence of significant clip migration during preoperative follow-up imaging after neoadjuvant chemotherapy. No complication related to the clip marking was noted and there was no difficulty in evaluating the treatment response to neoadjuvant chemotherapy. Among the breast-conserving surgeries performed, no cases were identified in which intraoperative loss of the marker clip had occurred. Conclusion Our study underscores the importance of intramammary marking clip systems before neoadjuvant chemotherapy. Placement of marker clips is advised to facilitate accurate tumor bed localization. With regard to digital breast tomosynthesis, its development continues to improve the quality of diagnostics and the therapy of breast cancer particularly for small breast cancer tumors or in neoadjuvant chemotherapy setting.

4.
Geburtshilfe Frauenheilkd ; 76(1): 59-64, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26855442

RESUMO

Introduction: Stereotactically-guided core needle biopsies (CNB) of breast tumours allow histological examination of the tumour without surgery. Touch imprint cytology (TIC) of CNB promises to be useful in providing same-day diagnosis for counselling purposes and for planning future surgery. Having addressed the issue of accuracy of immediate microscopic evaluation of TIC, we wanted to re-examine the usefulness of this procedure in light of the present health care climate of cost containment by incorporating the surgical 15-year follow-up data and outcome. Patients and Methods: From January until December 1996 we performed TIC in core needle biopsies of 173 breast tumours in 169 patients, consisting of 122 malignant and 51 benign tumours. Histology of core needle biopsies was proven by surgical histology in all malignant and in 5 benign tumours. Surgical breast biopsy was not performed in 46 patients with 46 benign lesions, as the histological result from the core needle biopsy and the result of the TIC were in agreement with the suspected diagnosis from the complementary breast diagnostics. A 15-year follow-up of these patients followed in 2013 and follow-up data was collected from 40 women. Results: In the 15-year follow-up of the 40 benign lesions primarily confirmed using CNB and TIC, a diagnostic sensitivity, specificity, positive and negative predictive value and accuracy of 100 % was found. Conclusion: TIC and stereotactically guided CNB showed excellent long-term follow-up in patients with benign breast lesions. The use of TIC to complement CNB can therefore provide immediate cytological diagnosis of breast lesions.

5.
Geburtshilfe Frauenheilkd ; 75(6): 588-596, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26166840

RESUMO

Introduction: Use of hormone therapy (HT) has declined dramatically in recent years. Some studies have reported that HT use before a diagnosis of breast cancer (BC) may be a prognostic factor in postmenopausal patients. This study aimed to examine the prognostic relevance of HT use before BC diagnosis. Methods: Four BC cohort studies in Germany were pooled, and 4492 postmenopausal patients with HT use data were identified. Patient data and tumor characteristics were compared between users and nonusers, along with overall survival (OS), distant metastasis-free survival (DMFS), and local recurrence-free survival (LRFS). Cox proportional hazards models were stratified by study center and adjusted for age at diagnosis, tumor stage, grading, nodal status, and hormone receptors. Results: Women with HT use before the diagnosis of BC were more likely to have a lower tumor stage, to be estrogen receptor-negative, and to have a lower grading. With regard to prognosis there were effects seen for OS, DMFS and LRFS, specifically in the subgroup of women with a positive hormone receptor. In these subgroups, BC patients had a better prognosis with previous HT use. Conclusions: HT use before a diagnosis of BC is associated with a more favorable prognosis in women with a positive hormone receptor status. It may be recommended that the prognostic factor HT should be documented and analyzed as a confounder for prognosis in studies of postmenopausal hormone-responsive breast cancers.

7.
Geburtshilfe Frauenheilkd ; 75(1): 72-76, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25684789

RESUMO

Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p < 0.05). Conclusion: The use of digital breast tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography.

8.
Geburtshilfe Frauenheilkd ; 74(8): 743-751, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25221342

RESUMO

Aim: Certification of breast centers helps improve the quality of care but requires additional resources, particularly for documentation. There are currently no published data on the actual staff costs and financial resources required for such documentation. The aim of this study was to determine the time and resources required to document a patient with primary breast cancer from diagnosis to the end of follow-up, to establish a database for future strategic decisions. Material and Methods: All diagnostic and therapeutic procedures of patients with primary breast cancer were recorded at the University Breast Center of Franconia. All time points for documentation were evaluated using structured interviews. The times required to document a representative number of patients were determined and combined with the staff costs of the different professional groups, to calculate the financial resources required for documentation. Results: A total of 494 time points for documentation were identified. The study also identified 21 departments and 20 different professional groups involved in the documentation. The majority (54 %) of documentation was done by physicians. 62 % of all documentation involved outpatients. The results of different scenarios for the diagnosis, therapy and follow-up of breast cancer patients in a certified breast center showed that the time required for documentation can be as much as 105 hours, costing € 4135. Conclusion: This analysis shows the substantial staffing and financial costs required for documentation in certified centers. A multi-center study will be carried out to compare the costs for certified breast centers of varying sizes with the costs of non-certified care facilities.

10.
Geburtshilfe Frauenheilkd ; 74(2): 152-156, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24741126

RESUMO

Introduction: Modern tablet PCs as the iPad are becoming more and more integrated into medicine. The aim of this study was to evaluate the display quality of iPads regarding digital mammography. Materials and Methods: Three experienced readers compared the display quality of the iPad 2 and 3 with a dedicated 10 megapixel (MP) mammography liquid crystal display (LCD) screen in consensus using the standardized Contrast Detail Mammography (CDMAM) phantom. Phantom fields without agreement between the readers were classified as "uncertain", correct 2 : 1 decisions were classified as "uncertain/readable". In a second step display quality of the three reading devices was judged subjectively in a side by side comparison. Results: The 10 MP screen was superior to both iPads in 4 (phantom-)fields and inferior in 2 fields. Comparing the iPads, version 3 was superior in 4 fields and version 2 was superior in 1 field. However these differences were not significant. Total number of "uncertain" fields did not show significant differences. The number of "uncertain" fields was 15 with the 10 MP screen, 16 with the iPad 2 and 17 with the iPad 3 (p > 0.05), the number of "uncertain/readable" fields was 4, 7 and 8, respectively. Subjective image quality of the iPad 3 and the 10 MP screen was rated superior to the iPad 2. Conclusion: The evaluated iPads, especially in version 3, seem to be adequate to display mammograms in a diagnostic quality and thus could be useful e.g. for patient consultation, clinical demonstration or educational and teaching purposes. However primary mammogram reading should still be performed on dedicated large sized reading screens.

11.
Ultraschall Med ; 35(4): 345-9, 2014 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-24563421

RESUMO

PURPOSE: The aim of this study was to evaluate the quality standard of the nationwide breast ultrasound training program of the German Society of Ultrasound in Medicine (DEGUM) through objective parameters. MATERIALS AND METHODS: 10 quality criteria, based on the recommendations of The National Association of Statutory Health Insurance Physicians (KBV), were defined for this study. All training units of the DEGUM received a questionnaire. The questionnaires and training material were analyzed. RESULTS: All units met the required criteria pertaining to the trainer's qualification, duration per training course and the maximum number of participants per ultrasound machine. Only 1 course did not fulfill the required 50 % practical training time. The requirements to participate in the graduate course (200 self-made and documented cases) were not clearly conceived and a defined training log could be improved. CONCLUSION: DEGUM breast ultrasound training offers trainees a high level of education based on the requirements of the KBV. Despite the high quality of training, the content of course announcements could be improved and an official and structured educational index could be meaningful.


Assuntos
Educação Médica Continuada/normas , Educação de Pós-Graduação em Medicina/normas , Programas Nacionais de Saúde , Sociedades Médicas , Ultrassonografia Mamária , Competência Clínica/normas , Currículo/normas , Feminino , Alemanha , Humanos , Garantia da Qualidade dos Cuidados de Saúde/normas , Indicadores de Qualidade em Assistência à Saúde/normas
12.
Radiologe ; 54(3): 217-23, 2014 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-24570108

RESUMO

Mammography is the central diagnostic method for clinical diagnostics of breast cancer and the breast cancer screening program. In the clinical routine complementary methods, such as ultrasound, tomosynthesis and optional magnetic resonance imaging (MRI) are already combined for the diagnostic procedure. Future developments will utilize investigative procedures either as a hybrid (combination of several different imaging modalities in one instrument) or as a fusion method (the technical fusion of two or more of these methods) to implement fusion imaging into diagnostic algorithms. For screening there are reasonable hypotheses to aim for studies that individualize the diagnostic process within the screening procedure. Individual breast cancer risk prediction and individualized knowledge about sensitivity and specificity for certain diagnostic methods could be tested. The clinical implementation of these algorithms is not yet in sight.


Assuntos
Neoplasias da Mama/diagnóstico , Detecção Precoce de Câncer/tendências , Previsões , Mamografia/tendências , Imagem Molecular/tendências , Imagem Multimodal/tendências , Técnica de Subtração/tendências , Algoritmos , Feminino , Humanos , Aumento da Imagem/métodos
13.
Ultraschall Med ; 35(1): 33-7, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24327473

RESUMO

INTRODUCTION: The potential of sonography in the examination of lung tissue is extremely limited by the air-filled alveoles of the lung. Only in special circumstances like pleural adhesion lesions, atelectasis or pneumonia can lung tissue be visualized by B-mode sonography. Real-time elastography was primarily applied to detect and visualize pulmonary lesions. METHODS AND PATIENTS: 8 patients with a total of 18 histologically proven metastases of the lung were included. All pulmonary lesions were detected by computed tomography. Sonographic examination was performed with a 7.5 MHz linear transducer (Acuson Antares premium edition, Siemens, Erlangen, Germany), including B-mode and real-time elastography (RTE). The mean distance between pleura and the lesions ranged from 0 to 2.5 cm. Two lesions were located in the upper right lobe, eleven lesions in the lower right and five in the lower left lobe. RESULTS: RTE was able to detect and visualize all 18 pulmonary lesions in contrast to B-mode. The size and distance of the lesions from the pleura correlated with the CT findings. CONCLUSION: In contrast to B-mode sonography, RTE is able to detect and visualize peripheral, non-pleural adherent pulmonary lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Leiomiossarcoma/diagnóstico por imagem , Leiomiossarcoma/secundário , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/secundário , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Uterinas/diagnóstico por imagem , Idoso , Neoplasias da Mama/patologia , Técnicas de Imagem por Elasticidade/instrumentação , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Leiomiossarcoma/patologia , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/patologia , Pessoa de Meia-Idade , Neoplasias Ovarianas/patologia , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Transdutores , Carga Tumoral , Neoplasias Uterinas/patologia
17.
Geburtshilfe Frauenheilkd ; 73(11): 1135-1138, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24771900

RESUMO

Introduction: A newly adapted clip system for intramammary marking during ultrasound-guided core needle biopsy for suspicion of breast cancer is described and evaluated here. Material and Method: Fifty patients with suspicion of breast cancer (cT2) had ultrasound-guided core needle biopsy using a newly adapted clip marker system (HistoCore™ and O-Twist Marker™). Subsequently, ultrasound follow-up and tomosynthesis scans were done to determine the location of the marker clips. Results: No dislocation of the marker clip was detected on ultrasound in 45 of 50 patients (90 %), and 5 patients (10 %) had a maximum dislocation of 5 mm along the x-, y- or z-axis. Tomosynthesis scans demonstrated precise placement without dislocation of the clip markers in 48 patients (96 %); 2 patients (4 %) had a maximum dislocation of 3 mm along the x-, y- or z-axis. Conclusion: The newly developed clip marker system, a combination of a single-use breast biopsy needle and a precise, length-adapted intramammary marker clip, represents a further improvement in oncological therapy. This is of particular importance for patients requiring subsequent neoadjuvant chemotherapy, as in cases with complete tumour remission, there is no target point for preoperative, ultrasound-guided wire marking.

18.
Geburtshilfe Frauenheilkd ; 73(12): 1228-1235, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24771903

RESUMO

Several advancements over the last decade have triggered the developments in the field of breast cancer risk research. One of them is the availability of the human genome sequence along with cheap genotyping possibilities. Another is the globalization of research, which has led to the growth of research collaboration into large international consortia that facilitate the pooling of clinical and genotype data of hundreds of thousands of patients and healthy control individuals. This review concerns with the recent developments in breast cancer risk research and focuses on the discovery of new genetic breast cancer risk factors and their meaning in the context of established non-genetic risk factors. Finally the clinical application is highly dependent on the accuracy of breast cancer risk prediction models, not only for all breast cancer patients, but also for molecular subtypes, preferably for those which are associated with an unfavorable prognosis. Recently risk prediction incorporates all possible risk factors, which include epidemiological risk factors, mammographic density and genetic risk factors.

19.
Geburtshilfe Frauenheilkd ; 73(2): 136-141, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24771910

RESUMO

Aim: Nodal status remains one of the most important prognostic factors in breast cancer. The cellular and molecular reasons for the spread of tumor cells to the lymph nodes are not well understood and there are only few predictors in addition to tumor size and multifocality that give an insight into additional mechanisms of lymphatic spread. Aim of our study was therefore to investigate whether breast characteristics such as mammographic density (MD) add to the predictive value of the presence of lymph node metastases in patients with primary breast cancer. Methods: In this retrospective study we analyzed primary, metastasis-free breast cancer patients from one breast center for whom data on MD and staging information were available. A total of 1831 patients were included into this study. MD was assessed as percentage MD (PMD) using a semiautomated method and two readers for every patient. Multiple logistic regression analyses with nodal status as outcome were used to investigate the predictive value of PMD in addition to age, tumor size, Ki-67, estrogen receptor (ER), progesterone receptor (PR), grading, histology, and multi-focality. Results: Multifocality, tumor size, Ki-67 and grading were relevant predictors for nodal status. Adding PMD to a prediction model which included these factors did not significantly improve the prediction of nodal status (p = 0.24, likelihood ratio test). Conclusion: Nodal status could be predicted quite well with the factors multifocality, tumor size, Ki-67 and grading. PMD does not seem to play a role in the lymphatic spread of tumor cells. It could be concluded that the amount of extracellular matrix and stromal cell content of the breast which is reflected by MD does not influence the probability of malignant breast cells spreading from the primary tumor to the lymph nodes.

20.
Geburtshilfe Frauenheilkd ; 73(2): 148-151, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24771912

RESUMO

Case Report: We report here on a 58-year-old patient with abnormal findings in the left breast on screening mammography (October 2012). In May 2008 the patient was diagnosed with rectal cancer, subsequently treated by surgical resection followed by radiochemotherapy. In September 2011 the patient was diagnosed with peritoneal cancer. Extravasation of folinic acid occurred during palliative chemotherapy, which was delivered through a surgically implanted port, placed prepectorally on the left side. The patient had not previously undergone breast surgery. The abnormal finding in the left breast was located at the 1-2 o'clock position. The mammogram showed extensive hyperdense nodules with predominantly round, fine granular calcifications. On sonography, the findings presented as a hypoechogenic, inhomogenous, partially diffuse, partly solid, partly cystic mass with individual calcifications and reduced echogenicity in the dorsal aspect. Strong densification of the left breast was found at the corresponding position on palpation. On computed tomography (CT) done during follow-up for rectal cancer, new streaky/pitted densifications were noted in the left breast. Based on the patient's previous history and the results of the breast diagnostics a diagnosis of extensive fat necrosis after folinic acid extravasation was made. No further measures were taken. The patient will continue to be screened using mammography. Conclusion: A good knowledge of the mammographic and sonographic features of fat necrosis can reduce the number of unnecessary biopsies. Careful consideration of the patient's prior medical history is very important in breast diagnostics and may often be decisive for the correct diagnosis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...